Actron Air AC error codes

0

 

Error Code Table

ESP Unit Error Fault Codes                   

Outdoor CPUWall ControllerFault/Function

0: Cooling Mode

1: Heating Mode

2: Heating compressor run time >20mins

3: Heating Defrost

4: LOW speed flashes every 30s: Over Heat or Anti-Freeze Protection mode (Reduced Capacity Mode)

5: Heating mode – indoor coil pre-heat

E6: Fault discharge temperature

E7: Fault outdoor coil sensor (open or closed circuit)

E8: Fault outdoor discharge sensor (open or closed circuit)

E9*: High or Low Pressure/Phase error (3 phase models only)*

E2: Fault indoor coil out sensor

E3: Fault room sensor(s) (open or closed circuit)

E4: Fault indoor coil sensor (open or closed circuit)

E5: Communication Fault

*E9 can also indicate a phase error (incorrect phase rotation or phase loss).

M Series (AM24 and AM7) Controller

OUTDOOR CPUAM24 Wall ControlAM7 Wall ControlFault/Function

0: Cooling Mode

1: Heating Mode

2: Heating Mode after 20 minutes of compressor run time. Defrost Standby.

3: Heating Mode De-ice cycle

5: Heating Mode Indoor coil pre-heat after defrost

E7: Fault: Outdoor coil sensor (open circuit)

E7: Fault: Outdoor coil sensor (closed circuit)

E9: Fault: High or Low pressure tripped (Note: Some models have discharge sensor, which will also give the same fault code.)

E5: Communication error between outdoor and indoor.

C Series (C7-1) Controller

OUTDOOR CPUC7 Wall ControlFault/Function

0: Cooling Mode

1: Heating Mode

2: Heating Mode after 20 minutes of compressor run time. Defrost Standby.

3: Heating Mode De-ice cycle

5: Heating Mode Indoor coil pre-heat after defrost

E5: Communication error between outdoor and indoor.

E7: Fault: Outdoor coil sensor open circuit

E7: Fault: Outdoor coil sensor short circuit

E9: Fault: High or Low pressure tripped (Note: Some models have discharge sensor, which will also give the same fault code.)

D Series 24 Hour (AECSN) and 7 Day (AEC7N) Controller

OUTDOOR CPUFault/Function

0: Cooling Mode

1: Heating Mode

2: Heating Mode after 20 minutes of compressor run time. Defrost Standby.

3: Heating Mode De-ice cycle

5: Heating Mode Indoor coil pre-heat after defrost

E5: Communication error between outdoor and indoor.

7: E1: Fault: Outdoor coil sensor open circuit

8: E1: Fault: Outdoor coil sensor closed circuit

9: (heat/cool flash): E2: Fault: High or Low pressure tripped (Note: Some models have discharge sensor, which will also give the same fault code.)

Notes:
  • Faults may not be displayed on the wall control until the fault occurs several times.
  • Phase error will be indicated by a red light on the 3-phase relay.
  • Phase correction must be applied to the incoming supply side.