Carrier Fault Codes



Indoor Error Codes



CodePossible CauseE0 Indoor unit EEPROM parameter error
E1 Indoor / outdoor units communication error
E3 Indoor fan speed has been out of control
E4 Indoor room temperature sensor T1 open circuit or short circuit
E5 Evaporator coil temperature sensor T2 open circuit or short circuit
EC Refrigerant Leakage Detection
F1 Outdoor ambient temperature sensor T4 open circuit or short circuit
F2 Condenser coil temperature sensor T3 open circuit or short circuit
F3 Compressor discharge temperature sensor T5 open circuit or short circuit
F4 Outdoor unit EEPROM parameter error
F5 Outdoor fan speed has been out of control
P0 IPM malfunction or IGBT over-strong current protection
P1 Over voltage or over low voltage protection
P2 High temperature protection of compressor top diagnosis and solution
P4 Inverter compressor drive error
P5 Mode conflict
P6 Compressor voltage protection





Outdoor Error Codes


CodePossible CauseE0 Outdoor EEPROM malfunction
E2 Indoor/outdoor units communication error
E3 Communication malfunction between IPM board and outdoor main board
E4 Open or short circuit of outdoor unit temperature sensor
E5 Voltage protection
E8 Outdoor fan speed malfunction
F1 No A Indoor unit coil outlet temperature sensor or connector of sensor is defective
F2 No B Indoor unit coil outlet temperature sensor or connector of sensor is defective
F3 No C Indoor unit coil outlet temperature sensor or connector of sensor is defective
F4 No D Indoor unit coil outlet temperature sensor or connector of sensor is defective
F5 No E Indoor unit coil outlet temperature sensor or connector of sensor is defective
P1 High pressure protection
P2 Low pressure protection
P3 Current protection of compressor
P4 Temperature protection of compressor
P5 High temperature protection of condenser
P6 IPM module protection





Other Carrier Error Codes


CodePossible CauseDN Communication error between main board and EXV.
EC Refrigerant leakage detection.
EE Memory card error.
EN Frequency limitation for module circuit protection.
EU Frequency limitation for module temperature protection.
FH Frequency limitation for freeze protection.
H1 Defrost or heating oil return cycle.
H3 Compressor overheat protection.
H5 IPM Protection.
H7 Compressor speed reduction.
HC PFC protection malfunction.
HE Compressor demagnetizing protection.
L9 Compressor high voltage protection.
LC Compressor start-up failure.
LD Compressor phase loss protection.
LE Compressor stalling.
LF Compressor over-speed protection.
LP Indoor and outdoor units mismatch.
PA Input current protection.
PC Current sensor malfunction.
PD Current sensor miss-wiring protection.
PF Inverter board ambient temperature sensor malfunction.
PH High voltage protection.
PL Low voltage protection.
PP Abnormal input AC voltage.
PU Capacitor charging malfunction.