Home Truma CP plus error codes Truma CP plus error codes Author - Sumit Raj July 22, 2023 0 Troubleshooting guide (Combi gas heater)Fault codeCauseRemedy#17Summer mode with empty water containerSwitch heater off and allow to cool. Fill boiler with water#18Warm air temperature exceeded:- Not all warm air ducts are connected- Warm air outlets blocked- Circulated air intake blocked- Check whether the 4 warm air ducts are connected- Check the individual outlet openings- Remove the circulated air intake blockage#21Room temperature sensor or cable faultyInspect the room temperature sensor cable, replace if faultyCheck the resistance of the room temperature sensor.15 °C – 16.2 kOhm / 20 °C – 12,6 kOhm / 25 °C – 10.0 kOhmReplace room temperature sensor if faulty#24Risk of low voltage. Battery voltage is too low < 10.4 VCharge battery#29FrostControl heating element has a short circuitDisconnect heating element plug from electronic control unit. Replace heating element#42Open window above cowl (window switch)Close window.#43Overvoltage > 16.4 VCheck battery voltage / voltage sources such as the charger#44Low voltage. Battery voltage is too low < 10.0 VCharge battery. If necessary replace old battery#45No 230 V operating voltage230 V fuse defectiveOverheating protection has been triggeredRestore 230 V operating voltageReplace 230 V fuse (see Combi operating instructions)Reset overheating protection (see Combi operating instructions)#112,#121,#122,#202,#211,#212Gas cylinder emptyGas cylinder or quick-acting valve in the gas supply line closedGas pressure regulation system iced upButane content in the gas cylinder too highCombustion air infeed or exhaust outlet is sealedGas pressure regulation system faultyReplacing a gas cylinderCheck gas supply and open valvesUse regulator heater (EisEx)Use propane. Butane is unsuitable for heating, particularly at temperatures lower than 10 °C.Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructionsInspect / replace gas pressure regulation system#255Heater has no 12 V power supplyNo connection between heater and control panelEnsure 12 V power supplyMake connection between heater and control panelTroubleshooting guide (Combi Gas heater) from year of construction 04/2018Fault codeCauseRemedy#255Heater has no 12 V power supplyNo connection between heater and control panelEnsure 12 V power supplyMake connection between heater and control panel#301,#417Overvoltage > 16.4 VCheck battery voltage / voltage sources such as the charger#302,#418Low voltage. Battery voltage is too low < 10.0 VCharge battery. If necessary replace old battery#303,#411Risk of low voltage. Battery voltage is too low < 10.4 VCharge battery#401Summer mode with empty water containerSwitch heater off and allow to cool. Fill boiler with water#402Warm air temperature exceeded:- Not all warm air ducts are connected- Warm air outlets blocked- Circulated air intake blocked- Check whether the 4 warm air ducts are connected- Check the individual outlet openings- Remove the circulated air intake blockage#407No 230 V operating voltage230 V fuse defectiveOverheating protection has been triggeredRestore 230 V operating voltageReplace 230 V fuse (see Combi operating instructions)Reset overheating protection (see Combi operating instructions)#412Open window above cowl (window switch)Close window.#507,#516,#517Gas cylinder emptyGas cylinder or quick-acting valve in the gas supply line closedGas pressure regulation system iced upButane content in the gas cylinder too highCombustion air infeed or exhaust outlet is sealedGas pressure regulation system faultyReplacing a gas cylinderCheck gas supply and open valvesUse regulator heater (EisEx)Use propane. Butane is unsuitable for heating, particularly at temperatures lower than 10 °C.Inspect openings for obstructions (slush, ice, leaves, etc.) and remove any obstructionsInspect / replace gas pressure regulation system#607Max. number of fault resets reachedWait 15 minutes and reset fault#621Room temperature sensor or cable faultyInspect the room temperature sensor cable, replace if faultyCheck the resistance of the room temperature sensor.15 °C – 16.2 kOhm / 20 °C – 12,6 kOhm / 25 °C – 10.0 kOhmReplace room temperature sensor if faulty#624FrostControl heating element has a short circuitDisconnect heating element plug from electronic control unit. Replace heating elementTroubleshooting guide (Combi Diesel heating system)Fault codeCauseRemedy#111Room temperature sensor or cable faultyInspect the room temperature sensor cable, replace if faultyCheck the resistance of the room temperature sensor.15 °C – 16.2 kOhm / 20 °C – 12,6 kOhm / 25 °C – 10.0 kOhmReplace room temperature sensor if faulty#122Lack of fuel due to insufficient fuel tank filling, tank has run empty and / or vehicle is on a slopeFill tank with fuel. Then fill the fuel line as described in “Initial startup” (see Combi Diesel operating instructions).#131No connection between heater and control panelMake connection between heater and control panel#132FrostControl heating element has a short circuitDisconnect heating element plug from electronic control unit. Replace heating element#150Warm air temperature exceeded:- Not all warm air ducts are connected- Warm air outlets blocked- Circulated air intake blocked- Check whether the 4 warm air ducts are connected- Check the individual outlet openings- Remove the circulated air intake blockage#151Water temperature exceeded in winter mode:Water temperature sensor excessive temperatureWarm air outlets blockedCirculated air intake blockedSwitch off appliance and allow it to cool down. Fill boiler with waterCheck the individual outlet openingsRemove the circulated air intake blockage#152Water temperature exceeded in summer mode:Water temperature sensor excessive temperatureWarm air outlets blockedCirculated air intake blockedSwitch off appliance and allow it to cool down. Fill boiler with waterCheck the individual outlet openingsRemove the circulated air intake blockage#160Undervoltage < 10.2 VCheck battery voltage, charge if necessaryShort-term immediate measure. Switch off major consumers or start up the vehicle engine until the heater starts to operate (approx. 4 minutes)Battery capacity inadequate, if necessary exchange old battery#161Overvoltage > 16.4 VCheck battery voltage / voltage sources such as the charger#162Open window above cowl (window switch)Close window.#164No 230 V operating voltage230 V fuse defectiveOverheating protection has been triggeredRestore 230 V operating voltageReplace 230 V fuse (see Combi operating instructions)Reset overheating protection (see Combi operating instructions)#170Risk of low voltage. Battery voltage is too low < 10.4 VCharge battery#255Heater has no 12 V power supplyNo connection between heater and control panelEnsure 12 V power supplyMake connection between heater and control panelTroubleshooting guide (air conditioning system)Fault codeCauseRemedy#1Failure (short circuit or broken cable), room temperaturesensorContact Truma Service#2Ice sensor (inside) triggeredInspect the filter and replace it if necessary#4Ice sensor (outside) triggeredKeep the air inlets / outlets on the roof free of obstructions such as leaves#8IR receiver unplugged or cable brokenCheck the connection of the IR receiver#17Voltage drop at 230 V power supplyCheck 230 V power supply Facebook Twitter Whatsapp Newer Older