Users of Voltas AC have recently started asking several queries about their systems. They have been looking for a list of Voltas AC problem codes and asking queries such, "What are Voltas AC error codes?" This is due to a variety of new codes that the manufacturers have inserted to tell consumers what is wrong with their air conditioning equipment. We were able to gather information on these Voltas AC issue codes that might benefit these people and provide answers to their inquiries, such as what Voltas AC error codes are. Let's get right in and learn more about Voltas AC problem codes without further ado.
Find the Voltas AC error codes below
- EE – The error code shows when you have an issue with Voltas indoor machine.
- E0 – The error code shows when there is an issue with the outdoor machine EE.
- E1 – The error code shows when you have an issue with the indoor fan.
- E2 – The error code shows when you have an issue with zero-crossing detection indoor fan.
- E3 – The error code shows when you have an issue with the sensor and indoor coil fault. You might need coil overheat protection.
- E4 – The error code shows when there is an issue with your Voltas indoor ambient temperature sensor.
- E5: The error code shows when there is a problem with the fan operation.
- E6: The error code shows when there is an outdoor and indoor machine communication issue.
- E8: The error code shows when there is a problem with outdoor communication.
- F1: The error code shows when you have a problem with the compressor starting up.
- F2: The error code shows when you have a problem with your compressor.
- F3: The error code shows when you have a problem with the IPM module.
- F4: The error code shows when you have a problem with the compressor shell roof.
- F5: The error code shows when you have a problem with the discharge temperature sensor.
- F6: The error code shows when you have a problem with the section temperature sensor.
- F7: The error shows when you have a problem with the coil temperature sensor or there is a temperature sensor fault.
- F8: The error code shows when you have a problem with the ambient temperature sensor.
- F9: The error code shows when you have a problem with your outdoor DC fan.
- P1: The error code shows when you have a problem with the machine air conditioning current protection.
- P2: The error code shows when you have an issue with the compressor phase current protection.
- P3: The error code shows when you have a problem with your outdoor unit air conditioner/ac voltage protection.
- P4: The error code shows when you have a problem with the DC voltage protection.
- P5: The error code shows when you have a problem with IPM over-high temperature protection.
- P6: The error code shows when you have a problem with the discharge temperature overheat protection.
- P7: The error code shows when you have a problem with the cooling coil anti-freezing protection.
- L4: The error code shows when you have a problem with the phase current samping.
- U1: The error code shows when there is a problem with the IPM overcurrent protection.
- U3: The error code shows when you have a problem with the compressor overcurrent protection.
- U4: The error code shows when you have a problem with over voltage protection.
- U5: The error code shows when you have a problem with low-voltage protection.
- U7: The error code shows when you have a problem with over-speed protection.
- 1E: Issue with outdoor unit room temperature sensor.
- 2E: Issue with unit pipe temperature sensor (outdoor unit).
- 3E: Issue with exhaust sensor.
- 4E: Module board needs to be replaced.
- 8E: Issue with PFC. Need to replace the module board.
- H1: Automatic defrosting
- H3: Halt for compressor overload protection.
- H4: Overload protection
- PL: protection against low voltage
- C5: Jumper cap malfunction