Voltas Inverter AC Error Code List

0

  


Voltas Inverter AC Error Code List 

Voltas Split AC Error Code List

Error CodeError Details
E1The trouble of indoor unit room temperature sensor
E2The trouble of indoor unit pipe temperature sensor
E3The trouble of PG motor
E5Wired controller communication failure
E6The EEPRO of indoor unit error
1EThe trouble og outdoor unit room temperature sensor
2EThe trouble of outdoor unit pipe temperatue sensor
3EThe trouble of exhaust sensor
4EThe EEPRO of indoor unit error ( outdoor unit). Replace the module board of outdoor unit
8EThe trouble of PFC. Replace the module board of outdoor unit
H1Automatic defrosting
H3Stop for compressor overload protection
H4Overload protection
H5Stop for IPM module protection
H6PG motor does not operate ( indoor fan motor)
HCPFC overcurrent malfunction
L9High protection of power
LPIndoor and outdoor units cant match with each other
PHHigh voltage protection
PLLow voltage protection
C5Jumper cap malfunction

List of Voltas Split AC error codes and their solutions:

Error CodeDescriptionSolution
E0Communication error between the indoor and outdoor units.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E1Indoor unit fan error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E2Outdoor unit fan error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E3Overcurrent error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E4Indoor unit temperature sensor error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E5Outdoor unit temperature sensor error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E6PCB error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E7IPM error.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E8Communication error between the PCBs.Switch on the AC after 10 minutes. If the error persists, contact Voltas customer care.
E9Indoor coil fault and sensor fault.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
E10Outdoor ambient temperature sensor fault.Turn off the AC, disconnect the power supply, and then reconnect it after 10 minutes. If the error persists, contact Voltas customer care.
 
 

 Here are some additional tips for troubleshooting Voltas Split AC error codes:
  • If the error code appears immediately after turning on the AC, it may be a problem with the power supply. Try unplugging the AC for a few minutes and then plugging it back in.
  • If the error code appears while you are using the AC, it may be a problem with the airflow. Make sure that the vents are not blocked and that the filter is clean.
  • If you have tried all of the troubleshooting steps and you are still getting error codes, you may need to have the AC serviced.

Here are some safety tips for using a Voltas Split AC:

  • Do not use the AC if it is damaged.
  • Do not use the AC if there is any liquid or food on the surface.
  • Do not use the AC if the power cord is damaged.
  • Do not use the AC if the AC is not level.
  • Do not use the AC if the AC is not properly installed.
  • Do not use the AC if the AC is not properly cleaned.

By following these safety tips, you can help to prevent accidents and keep your Voltas Split AC in good working order.

Please note that this is not an exhaustive list of Voltas Split AC error codes and solutions. For more information, you can consult your Voltas Split AC user manual.